AMCC 3ware 9650SE-2LP Uživatelská příručka Strana 307

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 361
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 306
Error and Notification Messages
www.3ware.com 295
See Also
See the Install Guide for your controller.
004F Cache synchronization skipped
Event Type
Warning
Cause
The cache synchronization that is normally performed when power is restored
after a power failure was skipped and write data is still being backed up in the
controller cache. This can occur if a unit was physically removed or became
inoperable during the power outage.
Action
Return missing drive(s) to the controller so that the missing write data can be
saved.
0050 Battery capacity test completed
Event Type
Information
Cause
The Battery Backup Unit has completed a battery capacity test.
The BBU is again able to backup the 3ware RAID controller and write cache
has been re-enabled for all units. (During the test, backup and write cache
were disabled).
0051 Battery health check started
Event Type
Information
Cause
The Battery Backup Unit periodically evaluates the health of the battery and
its ability to backup the 3ware RAID controller in case of a power failure.
This health check has started.
Zobrazit stránku 306
1 2 ... 302 303 304 305 306 307 308 309 310 311 312 ... 360 361

Komentáře k této Příručce

Žádné komentáře