AMCC 3ware 9650SE-2LP Uživatelská příručka Strana 288

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 361
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 287
Troubleshooting
276 3ware SAS/SATA RAID Software User Guide, Version 9.5.1
0026 Drive ECC error reported
Event Type
Error
Cause
Drive ECC errors are an indication of grown defects on a particular drive. For
redundant units, this typically means that dynamic sector repair has been
invoked (see message “0023 Sector repair completed” on page 274). For non-
redundant units (Single Disk, RAID 0 and degraded units), which do not have
another copy of the data, drive ECC errors result in the 3ware RAID
controller returning failed status to the associated host command.
Action
Schedule periodic verifications of all units so that drive ECC errors can be
found and corrected. If the unit is non-redundant a unit file system check is
recommended.
Under Windows, right-click on your drive icon and choose
Properties>
Tools> Check Now.
Under Linux or FreeBSD use fsck /dev/sda1. If you have more than one
SATA device, substitute the correct drive letter and partition number, such as
sdb2, for sda1.
See Also
“Enabling or Disabling Auto Verify for a Unit” on page 120
“Scheduling Background Tasks” on page 173
0027 DCB checksum error detected
Event Type
Error
Cause
The drive’s Drive Configuration Block (DCB) has been corrupted.
The 3ware RAID controller stores certain configuration parameters on a
reserved area of each disk drive called the Drive Configuration Block. As part
of power-on initialization, the 3ware RAID controller performs a checksum of
the DCB area to ensure consistency.
Zobrazit stránku 287
1 2 ... 283 284 285 286 287 288 289 290 291 292 293 ... 360 361

Komentáře k této Příručce

Žádné komentáře