AMCC 720-0140-00 Instalační příručka Strana 36

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 93
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 35
Chapter 2. CLI Syntax Reference
30 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5
/c
x
show numports
This command reports the port capacity (number of physical ports) of the
specified controller /cx.
Example:
//localhost> /c0 show numports
/c0 Number of Ports = 12
/c
x
show numunits
This command reports the number of units currently managed by the specified
controller /cx. This report does not include off-line units (or removed units).
Example:
//localhost> /c0 show numunits
/c0 Number of Units = 1
/c
x
show ctlbus
This feature only applies to 9550SX and 9590SE controllers.
This command reports the controller host bus type, bus speed, and bus width.
Example:
//localhost> /c0 show ctlbus
/c0 Controller Bus Type = PCIX
/c0 Controller Bus Width = 64 bits
/c0 Controller Bus Speed = 133 Mhz
/c
x
show exportjbod
This feature only applies to 9000 series controllers.
This command reports the current JBOD Export Policy: on, off, or Not
Supported.
Example:
//localhost> /c0 show exportjbod
/c0 JBOD Export Policy = Not Supported.
//localhost> /c1 show exportjbod
/c1 JBOD Export Policy = on
Zobrazit stránku 35
1 2 ... 31 32 33 34 35 36 37 38 39 40 41 ... 92 93

Komentáře k této Příručce

Žádné komentáře